5000 VRMS nominal. +/- 15 to 24V +/- 10% power supply, -45°C to +85°C, Isolation test voltage 12kVRMS/50 Hz/1 min, Primary and secondary connections on M5 threaded studs, Shield, For traction.
100 VRMS nominal.
1000 VRMS nominal.
1000 VRMS nominal. +/- 16 to 33 V power supply, 12 kVRMS as isolation test voltage, -25°C to +70°C, For traction.
1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, Secondary connections on M5 threaded studs, For traction.
1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.
1200 VRMS nominal.
1500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +85°C, Secondary connection on M5 threaded studs, For traction.
2000 VRMS nominal.
2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.
2000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +80°C, Primary and secondary connections on UNC 10-24 threaded studs, Shield, For traction.
2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.
2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -25°C to +70°C, For traction.
2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, Shield, For traction.
3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, For traction.
3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -25°C to +70°C, For traction.
3500 VRMS nominal.
3600 VRMS nominal. +/- 24 V power supply, -25°C to +70°C, For traction.
400 VRMS nominal.
4000 VRMS nominal.
4000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, For traction.
4000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Connection to primary by extra long studs, Secondary connections on M5 threaded studs, Shield, For traction.
500 VRMS nominal.
500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.
600 VRMS nominal.
600 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.
750 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, Shield, without electrolytic capacitors, For traction.
750 VRMS nominal. +/- 15 V power supply, -40°C to +80°C, Primary and secondary connections on M5 threaded studs, Shield, For traction.
800 VRMS nominal.