PCM

PCM, Points Condition Monitoring. Closed loop Hall effect based current transducers to monitor the points in trackside applications. DC, AC pulse currents' measurements from 5 to 30 A DC or RMS nominal with galvanic isolation. Compact split core design to make the maintenance easy. To be panel mounted. Aperture 15.6 mm diameter for the primary conductor crossing. Current output. Single supply + 24 V.

Model details

PCM 5-PR/SP2

5 A AC RMS nominal, -25°C to +55°C, IP 67, 4-20 mA DC True RMS current output (4 mA for 0 A, 12 mA for Ipn, 20 mA for 2xIpn), Secondary connections on cable.

Series
PCM
Measurement
電流センサ
Nominal Value
5 A
Measuring Range
25 A
Second. Nominal Signal
電流
Second. Nominal Signal Value
DC TRMS 4-20mA
Primary Signal
AC
Supply Voltage
外部DCユニポーラ
Supply Voltage Range
24 - 24 V
Accuracy
2 %
Op. Temperature
-25 °C / 55 °C
技術
クローズドループ・ホール効果
Mounting
パネル
アプリケーション
鉄道
PCM 5-PR/SP2
PICTURE
FRONT
BACK
LEFT
RIGHT
ダウンロード

Relative information

Check Stock

オンライン注文

シリーズ

同じシリーズの製品

PCM 10-P

10 ADC nominal, -40°C to +85°C, IP 67, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on Switchcraft connector.

PCM 10-P/SP1

10 ADC nominal, -25°C to +55°C, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on cable.

PCM 20-P

20 ADC nominal, -25°C to +55°C, IP 67, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on Switchcraft connector.

PCM 30-P

30 ADC nominal, -25°C to +55°C, IP 67, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on Switchcraft connector.

PCM 30-P/SP1

30 ADC nominal, -25°C to +55°C, 4-20 mA current output (4 mA for 0 A, 20 mA for +Ip), Secondary connections on cable.

PCM 30-P/SP2

30 ADC nominal, -25°C to +55°C, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on 3 m cable

注文