LV 100-VOLTAGE

Closed Loop Hall effect technology. DC, AC pulse voltage' measurements of 100 to 4000 VRMS nominal with galvanic isolation.To be panel mounted.

Model details

LV 100-1000

1000 VRMS nominal.

Series
LV 100-VOLTAGE
Measurement
Voltage
Nominal Value
1000 V
Measuring Range
1500 V
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 50 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 15 V
Accuracy
0.7 %
Op. Temperature
70 °C
Technology
Closed loop Hall effect
Mounting
Panel
Applications
Drives
Power Supplies
Renewable Energies
Traction
Welding
LV 100-1000
Download

Relative information

Check Stock

Order Online

Series

Product of the same series

LV 100-5000/SP1

5000 VRMS nominal. +/- 15 to 24V +/- 10% power supply, -45°C to +85°C, Isolation test voltage 12kVRMS/50 Hz/1 min, Primary and secondary connections on M5 threaded studs, Shield, For traction.

LV 100-1000/SP13

1000 VRMS nominal. +/- 16 to 33 V power supply, 12 kVRMS as isolation test voltage, -25°C to +70°C, For traction.

LV 100-1000/SP16

1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, Secondary connections on M5 threaded studs, For traction.

LV 100-1000/SP9

1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-1500/SP3

1500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +85°C, Secondary connection on M5 threaded studs, For traction.

LV 100-2000/SP15

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-2000/SP17

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +80°C, Primary and secondary connections on UNC 10-24 threaded studs, Shield, For traction.

LV 100-2000/SP18

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-2000/SP5

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -25°C to +70°C, For traction.

LV 100-2000/SP6

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-3000/SP12

3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, For traction.

LV 100-3000/SP3

3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -25°C to +70°C, For traction.

LV 100-3500/SP2

3600 VRMS nominal. +/- 24 V power supply, -25°C to +70°C, For traction.

LV 100-4000/SP2

4000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, For traction.

LV 100-4000/SP6

4000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Connection to primary by extra long studs, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-500/SP6

500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-600/SP6

600 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-750/SP4

750 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, Shield, without electrolytic capacitors, For traction.

LV 100-750/SP8

750 VRMS nominal. +/- 15 V power supply, -40°C to +80°C, Primary and secondary connections on M5 threaded studs, Shield, For traction.

Order

Contact Information