LXSR

Closed Loop Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 4 to14 ppm/°C, -40°C to + 105°C,  Reference access, Primary integrated conductors + aperture, 100 % fully compatible with CASR xx-NP&LTSR series

Model details

LXSR 15-NPS

15 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 6 ppm/°C, -40°C to +105°C, Ref. access, Primary integrated conductors + aperture, 100 % fully compatible with CASR 15-NP&LTSR 15-NP

Series
LXSR
Measurement
Current
Nominal Value
15 A
Measuring Range
51 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous 2.5 +/- 0.625 V
Primary Signal
AC + DC
Supply Voltage
External DC Unipolar
Accuracy
0.5 %
Op. Temperature
-40 °C / 105 °C
Technology
Closed loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Trackside
Welding
LXSR 15-NPS
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Check Stock

Order Online

Series

Product of the same series

LXSR 25-NPS

25 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 4 ppm/°C, -40°C to +105°C, Ref. access, Primary integrated conductors + aperture, 100 % fully compatible with CASR 25-NP&LTSR 25-NP

LXSR 6-NPS

6 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 14 ppm/°C, -40°C to +105°C, Ref. access, Primary integrated conductors + aperture, 100 % fully compatible with CASR 6-NP&LTSR 6-NP

Order

Contact Information