DVL

Voltage transducers for Industrial and Traction - for small and medium voltage measurements from 50 to 2000 VRMS with an unique compact design (30% lighter, 30% power saving) and excellent overall accuracy. 100 % compatible with previous generations of transducers in performance and footprint (LV100).

Model details

DVL 1000/SP1

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on burndy connector

Series
DVL
Measurement
Voltage
Nominal Value
1000 V
Measuring Range
1500 V
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 50 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 24 V
Accuracy
0.5 %
Op. Temperature
-40 °C / 85 °C
Technology
Insulation Digital Technology
Mounting
Panel
Applications
Traction
 DVL 1000/SP1 DVL
Order

Contact Information

Series

Product of the same series

DVL 1000

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 1000-UI

Unipolar and insulated DC measurement up to 1000 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 1000/SP5

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with shorter M5 threaded studs and,output connections on M5 threaded inserts.

DVL 1000/SP7

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input and output connections on cables

DVL 1000/SP8

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on cable.

DVL 1000/SP9

Bipolar and insulated measurement up to 1000 V, 6.66 V Voltage output, Input connections with M5 threaded studs and,output connections on M5 threaded inserts.

DVL 125

Bipolar and insulated measurement up to 125 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 150

Bipolar and insulated measurement up to 150 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 150-UI

Unipolar and insulated DC measurement up to 150 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 1500

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 1500-UI

Unipolar and insulated DC measurement up to 1500 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 1500/SP1

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on burndy connector

DVL 1500/SP5

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input and output connections on cables.

DVL 1500/SP6

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on cable.

DVL 1500/SP7

Bipolar and insulated measurement up to 1500 V, 7.5 V voltage output, Input connections with M5 threaded studs and,output connections on M5 threaded inserts.

DVL 1500/SP8

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input and output connections with M5 threaded studs.

DVL 150/SP1

Bipolar and insulated measurement up to 150 V, 50 mA current output, Input and output connections with M5 threaded studs.

DVL 2000

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 2000/SP1

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on Burndy connector.

DVL 2000/SP5

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input and output connections on cables.

DVL 2000/SP6

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on cable.

DVL 2000/SP9

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input and output connections with M5 threaded studs.

DVL 250

Bipolar and insulated measurement up to 250 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 250-UI

Unipolar and insulated DC measurement up to 250 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 50

Bipolar and insulated measurement up to 50 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 50-UI

Unipolar and insulated DC measurement up to 50 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 500

Bipolar and insulated measurement up to 500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 500-UI

Unipolar and insulated DC measurement up to 500 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 750

Bipolar and insulated measurement up to 750 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 750-UI

Unipolar and insulated DC measurement up to 750 V, 4-20 mA current output @ Ipn (4 mA @ 0A, 3 mA @ -Ipn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 750/SP3

Bipolar and insulated measurement up to 750 V, 62.5 mA current output, Input connections with M5 threaded studs and,output connections on Burndy connector.

DVL 750/SP4

Bipolar and insulated measurement up to 750 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on burndy connector

DVL 750/SP5

Bipolar and insulated measurement up to 750 V, 7.5 V voltage output, Input connections with M5 threaded studs and,output connections on M5 threaded inserts.