IT700-1000

Made for high accuracy. DC, AC pulse currents' measurements from 700 to 1000 ADC nominal with galvanic isolation. Excellent linearity, better than 3 ppm. High resolution. Initial offset between 50 to 60 ppm. Very low offset drift: between 0.5 to 4 ppm/K. Overall accuracy @ Ipn @ +25°C: between < +/- 0.0059% and < +/- 0.015%. ,Wide frequency bandwidth up to 500 kHz (+/- 3 dB). Fluxgate technology. Electrostatic shield between primary and secondary circuit. Power supply +/-15 V. Operating temperature range from +10 to +50°C. D-Sub 9 male interface output. Current output. Really quick response time (<250 µs)
Model details

IT 700-SB ULTRASTAB

High accurate current transducer for 700 ARMS nominal. +/- 10 V output. Linearity error 30 ppm. Sensitivity error 50 ppm.

Series
IT700-1000
Measurement
Current
Nominal Value
700 A
Measuring Range
700 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous 10 V
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 15 V
Accuracy
0.0141 %
Op. Temperature
10 °C / 50 °C
Technology
Closed loop Fluxgate IT type
Mounting
Panel
Applications
High Precision
IT 700-SB ULTRASTAB
PICTURE
FRONT
BACK
LEFT
RIGHT
Check Stock

Order Samples

Series

Product of the same series

Order

Contact Information