Rack mounted (fix gain or programmable) current transducers. Made for ultra high accuracy. 14 models. DC, AC pulse currents' measurements from 40 to 24000 ADC nominal with galvanic isolation. Excellent linearity, from 1 to 10 ppm. High resolution. Initial offset: < 2 ppm. Very low offset drift: from 0.1 to 0.6 ppm/K. Overall accuracy @ Ipn @ +25°C: between < +/- 3 ppm and < 12 ppm. Wide frequency bandwidth from DC up to 500 kHz (+/- 3 dB). Closed-Loop Fluxgate technology. Electrostatic shield between primary and secondary in the heads. Power supply 100-240 VAC, 50-60 Hz. Products made up of one measuring head in a side and one separated electronic in the other side connected together via a cable. Operating temperature range from +10 to +40°C for the electronics and from 0 to +55°C for the measuring heads. D-Sub 15 female connector used for the analogue output. D-Sub 9 male connector used for the status output. Really quick response time (from <1 µs to <2 µs). 600 A and 2000 A models are programmable in the needed range thanks to some programming plugs to add on the measuring heads. 5 measuring heads are available according to the current to measure and to the aperture needed for the primary conductor (from 25.4 mm up to 150.3 mm diameter).

Model details

ITZ 2000-SB FLEX ULTRASTAB

High accurate current transducer. 2000 ADC nominal. Current output and voltage +/- 10 V output.

Series
ITZ
Measurement
Current
Nominal Value
2000 A
Measuring Range
2000 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous 10 V
Primary Signal
AC + DC
Supply Voltage
External AC
Supply Voltage Range
100 - 240 V
Accuracy
0.0064 %
Op. Temperature
10 °C / 40 °C
Technology
Closed loop Fluxgate IT type
Mounting
Panel
Applications
High Precision
 ITZ 2000-SB FLEX  ULTRASTAB  ITZ
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Series

Product of the same series

ITZ 2000-SBPR FLEX ULTRASTAB

High accurate current transducer. 2000 ADC nominal. Current output and voltage +/- 10 Volt output, Programmable in the range 125 A to 2000 A with programming plugs

ITZ 2000-SPR FLEX ULTRASTAB

High accurate current transducer. 2000 ADC nominal. Current output, Programmable in the range 125 A to 2000 A with programming plugs