LT2005

Closed Loop Hall effect. DC, AC pulse currents' measurements of 2000 ARMS nominal with galvanic isolation. To be panel mounted. Aperture 60.5 x 20.5 mm or 56 mm diameter for the primary conductor crossing. Excellent accuracy, good response time, Current output, 0°C to + 70°C. Dual supply +/- 15 to +/- 24V.

Model details

LT 2005-S/SP3

1100 ARMS nominal. +/- 15 V power supply, -30°C to +70°C, Shield, Hall cell at the bottom centered, For traction.

Series
LT2005
Measurement
Current
Nominal Value
1100 A
Measuring Range
2000 A
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 220 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 15 V
Accuracy
0.6 %
Op. Temperature
-30 °C / 70 °C
Technology
Closed loop Hall effect
Mounting
Panel
Applications
Traction
 LT 2005-S/SP3 LT2005
Download

Relative information

Order

Contact Information

Series

Product of the same series

LT 2005-T/SP2

2000 ARMS nominal. Special busbar integrated, Turns ratio 1/4000, -40°C to +70°C, For traction.

LT 2005-T/SP22

2000 ARMS nominal. Special busbar integrated, -25°C to +70°C, +/- 24 V power supply, Test winding 100 turns, Shield, Hall cell at the bottom centered, For traction.

LT 2005-S/SP15

2000 ARMS nominal. Turns ratio 1/5000, +/- 24 V power supply, -25°C to +70°C, Shield, Output on connector AMP CPC, Hall cell at 90°, For traction.

LT 2005-S/SP2

2000 ARMS nominal. Turns ratio 1/4000, -40°C to +70°C, For traction.